18
Operations
Double Scrub
For floors which are heavily soiled or have thick accu-
mulations of floor finish may not clean sufficiently with
one pass. In these cases it will be necessary to double
scrub.
1. To double scrub, make the first pass over the
surface being cleaned with both squeegees up,
vacuum off, the solution on and brushes down.
This allows the solution to stay in contact with the
soil while loosening the surface accumulation with
the brushes. Allow time for the first application to
stay in contact with the floor. Length of time
between the first and second pass depends on
amount of accumulation and the type of chemical
being used. A second scrubbing with both
squeegees down and again the solution and
brushes on will further loosen soil. The additional
application of solution will further assist the difficult
cleaning job.
FOR SAFETY: When using machine, go slow on
inclines and slippery services.
Emptying And Cleaning Tanks
1. Park the machine next to a floor drain. Drain hose
is on left rear corner of the machine.
2. Turn the machine power off and set parking brake,
if your machine is equipped with this option.
Solution Tank
1. Loosen small drain hose from the retainer, then
lower hose in direction of the drain.
2. Remove the solution tank cover.
3. Flush the solution tank out with clean water and
run several gallons of clean water through
systems. Do not use water hotter than 140°F
(60°C) to clean tank. Damage may occur.
NOTE: Never allow solution to remain in tank.
Damage to tank, seals and valves could occur.
4. Secure drain hose into the retainer.
Recovery Tank
1. Unhook the large drain hose from the retainer.
Lower hose in direction of the drain then unscrew
the T-handle on plug enough to loosen plug. Do
not stand in front of end of hose. Recovered
solution will come out with force. Slowly remove
plug from drain hose.
2. Remove the recovery tank dome. Flush the
recovery tank out with clean water. Do not use
water hotter than 140°F (60°C) to clean tank.
Damage may occur.
3. Clean off the float shut-off system and inspect for
free movement of float. The float shut-off system is
located in the rear of the recovery tank.
4. Replace the drain plug and secure drain hose in
bracket.
5. If machine is to be stored, leave the recovery tank
dome off.
86037150 SCX364
SOLUTION
TANK DRAIN
TANK COVER
RECOVERY
TANK DRAIN
RECOVERY
TANK COVER