Shunt Replacement
This pad pressure meter adjustment is factory set. Over
the course of time it may become necessary to adjust
this setting using the slotted connection on the shunt.
Check the amp range when nuisance tripping of the
pad motor controller indicates that the shunt may be out
of adjustment.
1. Connect a DC ampere meter to the positive battery
lead. Running the machine with a pad, lower the
pad to the floor until it is operating at 60 5 amps.
2. Moving the wire in the slot, adjust the pad pressure
meter until the needle sets at the line between the
blue and red areas.
Burnisher Motor Carbon Brush
Replacement
1. Mark location of cable lugs on motor housing.
2. Remove four screws from top cover. Remove
cover from motor.
3. Remove four screws from brush housing. Lift brush
housing off of motor commutator.
4. Clean excessive carbon deposits off of motor
components with compressed air.
5. Prepare new brush assembly for use by inserting
individual brush springs into brush guides. Check
each brush to ensure proper movement after
installing springs.
6. Locate new brush assembly according to locations
marked in step 1. Depress brushes as required to
insert brush housing over commutator.
7. Check that motor spins freely with new brushes
installed. Replace four screws to secure brush
housing. Replace motor cover.
SHUNT
Moves
needle
toward
RED
range
Moves
needle
toward
GREEN
range
Slotted
Connection
From
Meter
To
Meter
See wiring diagram for lead connection